Skip to main content
You’ve already built dashboards showing traffic, errors, latency, and saturation — but dashboards only help if someone is watching them. No one is casually monitoring Grafana at 3 AM. Alerting exists to notify humans about important, time-sensitive problems that require human judgment and action. The Google SRE Handbook recommends that every alert should correspond to a high-stakes situation that requires human intervention. If no action is required, it should not be an alert. Too many teams fail not because alerts are missing, but because alerts are too noisy or too sensitive. Alerts that fire constantly lose credibility and are ignored.
Alert fatigue is real: when alerts are noisy and frequent, on-call engineers start muting channels and ignoring notifications. When a real incident occurs, it can be mistaken for background noise.
A slide titled "Alert Fatigue" shows a dark monitoring dashboard with request rates, latencies, error rates and pod statuses on the left. On the right is a pile of overlapping "noise" cards labeled Infrastructure/Application/Business Noise and an icon of a stressed person clutching their head.
Rule of thumb: alert on symptoms, not causes. Symptoms reflect what users actually experience — errors, slow responses, and failed requests. Causes are internal signals (high CPU, thread pool exhaustion, GC pauses). Users don’t care that CPU reached 90%; they care that their request failed.
Prefer alerts that describe user-facing impact. Use internal/system metrics for context or as early warnings, not as the primary, paged alert unless they clearly require immediate action.
A presentation slide titled "Alert on Symptoms, Not Causes" that contrasts user-facing symptoms with internal root causes. The left column lists Errors, Slow responses, and Failed requests while the right column lists High CPU, Thread pool exhaustion, and Garbage collection pauses.
Map this guidance to the golden signals (errors, latency, saturation, traffic). Below are practical recommendations for each:
  • Errors: Treat errors as symptoms. If user-visible errors increase and breach your SLO, that is actionable and should page the on-call engineer.
  • Latency: Alert on percentiles (P95, P99) rather than averages. Percentiles reveal tail latency that impacts a subset of users even if the mean looks fine.
  • Saturation: These are often root causes, not direct symptoms. High CPU, memory, or queue lengths can indicate an impending outage — useful for warnings, but usually not for immediate paging unless they cross a clear emergency threshold.
  • Traffic: Traffic changes are contextual. A spike can be good (successful campaign); a drop might be normal. Use traffic to interpret other alerts — e.g., an elevated error rate with high traffic is more concerning than the same error rate at low traffic.
A slide titled "Golden Signals and Alerting" with four labeled quadrants: Errors, Latency, Saturation, and Traffic. The Traffic quadrant shows a blue "Context" box stating "Error rate above 5% AND traffic above baseline."
For quick reference, here’s a concise mapping of each golden signal to recommended alert behavior: Design alerts with a simple mental model: would a human need to intervene right now? Good alerts should be:
  • Actionable — they point to what to do or what subsystem to investigate (service name, logs, runbook link).
  • Indicative of user impact — they reflect user-facing symptoms or clear SLO violations.
  • Trustworthy — they are rare enough that on-call engineers believe and act on them.
Later, we’ll configure Grafana-managed alerting and translate these principles into concrete rules, thresholds, and notification workflows. Links and references:

Watch Video